Plug-In Repeat Cycle Timers - TNKA Timers
Plug-In Repeat Cycle Timers - TNKA Timers
|
|
 |
TNKA Timers
The TNKA Repeat Cycle units meet the needs of customers who require IC digital timing circuits with octal, magnal round and QC bases for plug-in installation. The units are available in SPDT, DPST and DPDT relay forms up to 10 amp with fixed or adjustable time periods. |
Timing Mode
Application of input voltage to the timer starts the “On” time delay, and energizes the relay. At the end of the “On” time delay, the relay is de-energized, and the “Off” time delay starts. At the end of the “Off” time delay, the load is again energized, the timer returns to the “On” time delay, and the cycling continues as long as input voltage is applied. Removal of the input voltage resets the timer. The “On” and “Off” times are equal.
|
 |
|
FEATURES |
-
CMOS IC digital timing
-
Multi-board construction
-
Relays are sealed
-
Proven circuitry
-
Standard octal (8 pin), magnal (11 pin) plug-ins or 4.75 mm (.187") blade terminal mountings
- Fixed or variable time adjustment
|
-
Optional remote time adjustment
-
Timing ranges from .05 to 1000 seconds standard (special time settings and ranges up to 72 hours also available)
-
0.1% Repeat accuracy
- 100% Operational testing before shipping

|
| BASIC WIRING AND DIMENSIONS |
 |
| SPECIFICATIONS |
|
Input Voltages:
- VAC: 12, 24, 120, 230, 50/60 Hz
- VDC: 12, 24
Operating Voltage: 20% of nameplate voltage Relay Contact Ratings: 5 amps DPDT, 10 amps DPDT Optional Repeat Accuracy: 0.1% under fixed operating conditions Reset Time: 50 milliseconds Tolerances:
Fixed: 10%, Optional: 5%, 1% Variable: +20%, -0, Optional: +10%, -0%
Note:Tolerances on variable units are with respect to upper limit only. Timers with time periods greater than 10 sec. will have a 100 to 1 ratio, i.e., 1 to 100 seconds, 30 to 3000 seconds. Timers with the time periods less than 10 sec., will have a 10 to 1 ratio, i.e., .99 to 9.9 seconds, .5 to 5 seconds.
|
|
Life Expectancy:
- Mechanical: 1 million operations
- Electrical: Up to 100,000 operations at full current load
Protection:
- Polarity Protection: All DC units have reverse polarity protection.
- Transient Protection: 25 joules
Temperature Ranges:
- Storage: -40° C to +85° C
- Operating: -25° C to +85° C
Housing Material: High impact, UL approved black Lexan |
| SELECTION PROCEDURE |
| Mode of Operation |
Series |
Input Voltage |
Time Ranges |
Tolerance |
Time Adjustment Method |
Base Style |
Options |
| Repeat-Cycle On/Off Delay |
TNKA |
- 120 VAC
- 230 VAC
- 24 VAC
- 24 VDC
- -
- -
- 12 VDC
- special ac
- special Dc
|
|
VARIABLE TIME PERIODS
|
0001 .1 to 1 sec. 0010 .1 to 10 sec. 0100 1 to 100 sec. 1000 10 to 1000 sec.
Any range up to 72 hours available on special order.
|
|
FIXED TIME PERIODS
|
Specify time in full seconds or hours followed by the letter “S” or “H” and the decimal amount of the main time unit.
Examples:
- 5S5 is 5.5 seconds
- 5H5 is 5.5 hours
|
|
X Standard (Fixed: 10% Variable: +20% -0%)
E
F
G Optional (Adjust.: +10%, -0%) |
A
B Variable with external potentiometer AOT supplied
C
D Fixed time with customer supplied resistor |
1
2
3 11 Pin Spade .187 Quick Connect |
X
H 10 amps (8 amps ul Recognized for usa and Canada.) |
|
|