All our state/event recorders are devices which sense input transitions or contact closures from external sources such as transducers and/or state initiators. STATE recorders time stamp when any change of state (+ and -) occurs.
EVENT recorders time stamp when predefined unidirectional change (+ or -) occurs. Memory is nonvolatile solid state. The device can be started and stoped directly from your PC and is fully supported by our graphical Windows® based software.
PULSE101 senses and records the number of pulses/contact closures that occur over the user defined period. Store user defined units such as gollons/min. as well as scale factors and offset values. Easily linearize and scale any transducer that provides a pulse or contact closure output.
STATE101 Features
Memory 13,107
Form Factor A-1
Battery Factor 1
Battery Life 1 yr.
Weight 1 oz (30 g)
STATE110 Features
Memory 13,107
Form Factor A-2
Battery Factor 1
Battery Life 10 yr.
Weight 1 oz. (30 g)
QUADSTATE Features
OCTSTATE Features
EVENT101 Features
Memory 13,107
Form Factor A-1
Battery Factor 1
Battery Life 1 yr.
Weight 1 oz. (30 g)
EVENT110 Features
Memory 13,107
Form Factor A-2
Battery Factor 1
Battery Life 10 yr.
Weight 1 oz. (30 g)
PULSE101 Features
Memory 16,383
Form Factor A-1
Battery Factor 1
Battery Life 1 yr.
Weight 1 oz. (30 g)
General State Specifications
Input Connection: Removable screw terminal
Input Low: <0.4V
Input High: >2.7V
Input Range: 0 to 30V
Input Impedance: >1 Kohm
Time Resolution: 1 second (reading rate dependent)
Visual Indicator: LED flahses at selected reading rate
Engineering Units: Use may define units up to 10 characters in length. This value is stored in device.
Scale Factor: User may program any desired scaling factor from ±1.000E-31 to ±9.999E+31. The scaling factor is stored within the device.
Real Time Recording: When used with PC.
Reading Interval: 1/second to 1 every 12 hours.
Replaceable Battery: 1 year typical life at 25 °C
Data Format: Date and time stamped state changes (on/off).
Time Accuracy: +/-1 minute/month at 20 °C, no RS232 in use.
Computer Interface: PC serial or RS232C COM
Software: Windows 95/98/ME/NT/2000/XP compatible
Operating Environment: -40 to +80 °C, 5 to 96 RH non-condensing.
General Event Specifications
Input Connection: Removable screw terminal
Input Low: <0.4V
Input High: >2.7V
Input Range: 0 to 30V
Input Impedance: >1 Kohm
Minimum Input Active (Low) Time: 1 ms
Time Resolution: 1 second (reading rate dependent)
Visual Indicator: LED flahses at selected reading rate
Engineering Units: Use may define units up to 10 characters in length. This value is stored in device.
Scale Factor: User may program any desired scaling factor from ±1.000E-31 to ±9.999E+31. The scaling factor is stored within the device.
Real Time Recording: When used with PC.
Reading Interval: 1/second to 1 every 12 hours.
Replaceable Battery: 1 year typical life at 25 °C
Data Format: Date and time stamped state changes (true/false).
Time Accuracy: ±1 minute/month at 20 °C, no RS232 in use.
Device records one event per user reading interval.
General Pulse Specifications
Maximum Pulse Rate: 100 per second (10 ms)
Minimum Pulse Width/Contact Closure Time: 1 ms
Input Signal: TTL, Internal pull-up, +30 Volts max.
Input Connection: Removable Screw Terminal
Input Impedance: >1 Kohm
Start Time: Software programmable start time and date, up to six months in advance.
Real Time Recording: When used with a PC
Scale Factor: User may program any desired scaling factor from ±1.0000E-31 to ±9.9999E+31. The scaling factor is stored within the device.
Offset Value: Software Programmable to any value from ±1.0000E-31 to ±9.9999E+31. The factor is stored in the device.
Reading Interval: 1/second to 1 every 12 hours.
Visual Indicator: LED flashes at reading rate.
Data Format: Date and time stamped, V, mV, µV, user defined engineering units.
Time Accuracy: ±1 minute/month at 20 °C, no RS232 in use.
Specifcations
|
STATE/EVENT/PULSE
|
|
|
|
Item No.
|
Name
|
Description
|
|
|
5399-0707
|
State 101
|
State Recorder
|
|
|
5399-0708
|
State 110
|
Similar to State 101 w/ 10 Yr Battery & Fast Data Retrieval.
|
|
|
5399-0704
|
Quad State
|
4 Channel State Recorder
|
|
|
5399-0705
|
Oct State
|
8 Channel State Recorder
|
|
|
5399-0703
|
Event 101
|
Event Recorder
|
|
|
5399-0706
|
Event 110
|
Similar to Event 101 w/ 10 Yr Battery & Fast Data Retrieval.
|
|
|
5399-0701
|
Pulse 101
|
Pulse Recorder
|
|
Need to Data Log RPM? Find our how
|
|